Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Tomography ; 9(2): 621-632, 2023 03 08.
Artigo em Inglês | MEDLINE | ID: mdl-36961009

RESUMO

Evaluation of patient radiation dose after the implementation of a high kV technique during a cerebral angiographic procedure is an important issue. This study aimed to determine and compare the patient radiation dose of intracranial aneurysm patients undergoing cerebral angiography using the conventional and high kV techniques in a retrospective study and a phantom study. A total of 122 cases (61 cases with conventional technique and 61 cases with high kV technique) of intracranial aneurysm patients, who underwent cerebral angiographic procedure and met the inclusion criteria, were recruited. The radiation dose and the angiographic exposure parameters were reviewed retrospectively. The radiation dose in the phantom study was conducted using nanoDotTM optically stimulating luminescence (OSLD), which were placed on the scalp of the head phantom, the back of the neck, and the phantom skin at the position of the eyes. The standard cerebral angiographic procedure using the conventional and high kV techniques was performed following the standard protocol. The results showed that the high kV technique significantly reduced patient radiation dose and phantom skin dose. This study confirms that the implementation of a high kV technique in routine cerebral angiography for aneurysm diagnosis provides an effective reduction in radiation dose. Further investigation of radiation dose in other interventional neuroradiology procedures, particularly embolization procedure, should be performed.


Assuntos
Aneurisma Intracraniano , Humanos , Angiografia Cerebral/métodos , Aneurisma Intracraniano/diagnóstico por imagem , Estudos Retrospectivos , Doses de Radiação , Imagens de Fantasmas
2.
Surg Radiol Anat ; 45(4): 367-374, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36763101

RESUMO

PURPOSE: Anatomical variations of the internal carotid artery (ICA) can cause complications during endovascular treatments. Therefore, the aim of this study was to investigate the features of the ICAs obtained from 2D digital subtraction angiography (2D DSA). METHODS: The morphometrics and angles of the ICA segments from 2D DSA images from a total of 100 patients (45 males and 55 females) were investigated. The lengths (L1-3), angles (A1-3), and diameters (D1-6) through the ICA measurement points (five segments: C2 [petrous], C3 [lacerum], C4 [cavernous], C5 [clinoid], C6 [ophthalmic]) were systemically recorded by two observers. All measured parameters were compared for both sexes and sides. RESULTS: The lengths (mm) and angles of the ICA were 7.20 ± 2.22 (L1), 15.71 ± 2.32 (L2), 10.99 ± 1.66 (L3) and 109.31 ± 17.77 (A1), 107.87 ± 20.51 (A2), 80.81 ± 16.33 (A3), respectively. There were no differences in the angulations of the A1-A3 segments between the sexes (p > 0.05). The L2 (C3-C4) was significantly longer in males, but only the left side of females showed a greater length (p < 0.05). The averaged mean diameters of the ICA (D1-6) in both sexes were 4.17 ± 0.55 mm. However, the diameters of the D1-D6 from left and right sides of males except the right D6 were significantly longer than those of females (p < 0.05). Also of significance was that the right diameters of females (D1) and males (D1 and D2) were shorter compared to left sides. CONCLUSION: This study demonstrates some differences in lengths, diameters, and angles in both sexes and sides of the normal ICA. Neurosurgeons and neurointerventionalists should be aware of such variations when operating, performing interventional procedures, and interpreting 2D DSA.


Assuntos
Artéria Carótida Interna , Masculino , Feminino , Humanos , Artéria Carótida Interna/diagnóstico por imagem , Estudos Retrospectivos , Angiografia Digital
3.
J Food Biochem ; 46(4): e13909, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34423456

RESUMO

This study aims to investigate the effect of Polygonum odoratum leaf extract (POE) on oxidative stress markers and cell death induced by low dose ionizing radiation (LDIR) in Raw 264.7 cells. The biological activities, chromatographic fingerprint, and cytotoxicity of POE were investigated. To determine the radioprotective effect of POE, Raw 264.7 cells were incubated with POE for 1 hr prior to 100 mGy x-irradiation. The cell viability, oxidative stress damage marker (malondialdehyde level; MDA), and endogenous antioxidant markers (superoxide dismutase: SOD, catalase: CAT, and glutathione peroxidase: GSH-Px) were also determined. The results showed that POE contained 8 essential substances and exhibited a potent antioxidant without any cytotoxicity. It was found that POE significantly decreased the MDA level and activated cell viability, SOD, CAT, and GSH-Px activities. The results from this study indicate that POE is a potent antioxidant, which can be developed as a radioprotector for diagnostic procedures. PRACTICAL APPLICATIONS: Polygonum odoratum leaf extract (POE) is a potent antioxidant that attenuates oxidative stress and cell death induced by low dose ionizing radiation (LDIR). POE might protect against cell damage from LDIR, particularly in diagnostic radiology procedures. Therefore, the development of functional food containing POE might be beneficial for patients who plan to undergo the diagnostic radiology procedure. The functional food containing POE might prevent stochastic and deterministic effects for these patients.


Assuntos
Antioxidantes , Estresse Oxidativo , Extratos Vegetais , Polygonum , Animais , Antioxidantes/metabolismo , Antioxidantes/farmacologia , Morte Celular , Camundongos , Extratos Vegetais/química , Extratos Vegetais/farmacologia , Polygonum/química , Células RAW 264.7 , Radiação Ionizante , Superóxido Dismutase/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...